PA6 BL2340-H SINOPEC BALING
65
Form:Granules | Grade:Enhanced level
Properties:
High mobilityLow viscosity
Typical Applications:
Automotive ApplicationsHome appliance components
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive Applications | Home appliance components |
| Properties: | High mobility | Low viscosity |
Certificates
No Data...
Technical Data Sheet
| other | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| characteristic | 适合于工业用丝.包装膜及高强耐磨结构件等 | |||
| Color | 纯白色透明 | |||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Charpy Notched Impact Strength | ASTM D256/ISO 179 | 28.3 | kg·cm/cm(J/M)ft·lb/in | |
| Elongation at Break | ASTM D638/ISO 527 | 231.3 | % | |
| tensile strength | ASTM D638/ISO 527 | 64.6 | kg/cm²(MPa)[Lb/in²] | |
| Rockwell hardness | ASTM D785 | 75 | ||
| Bending modulus | ASTM D790/ISO 178 | 1992 | kg/cm²(MPa)[Lb/in²] | |
| bending strength | ASTM D790/ISO 178 | 84.9 | kg/cm²(MPa)[Lb/in²] | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | HDT | ASTM D648/ISO 75 | 75 | ℃(℉) |
| Melting temperature | 219-225 | ℃(℉) | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D792/ISO 1183 | 1.157 | ||
| Shrinkage rate | ASTM D955 | 1.42 | % | |
| melt mass-flow rate | ASTM D1238/ISO 1133 | 3.35 | g/10min | |
| Water absorption rate | ASTM D570/ISO 62 | 《0.07 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | ASTM D257/IEC 60093 | 6.0*10 12 | Ω | |
| Dielectric constant | ASTM D150/IEC 60250 | 1.5 | ||
| Volume resistivity | ASTM D257/IEC 60093 | 2.5*10 14 | Ω.cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.