PA6 BGK-30X EMS-CHEMIE Netherlands
48
Form:Granules | Grade:Injection grade
Properties:
Glass fiber reinforcedHigh impact resistanceFiller: glass beads fibe30%Filler by weight
Typical Applications:
Home appliance componentsAutomotive interior partsElectrical applications
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Home appliance components | Automotive interior parts | Electrical applications |
| Properties: | Glass fiber reinforced | High impact resistance | Filler: glass beads | fibe | 30% | Filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | -30°C | kJ/m² | 50 | |
| 23°C | kJ/m² | 65 | 75 | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Flammability level | 0.8mm | HB | -- | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | 7000 | MPa | ||
| tensile strength | Break | MPa | 140 | 80.0 |
| Tensile strain | Break | % | 3.0 | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Continuous use temperature | --3 | °C | 160 | -- |
| Melting temperature | °C | 222 | -- | |
| Linear coefficient of thermal expansion | MD | cm/cm/°C | 3.5E-05 | -- |
| TD | cm/cm/°C | 7E-05 | -- | |
| Hot deformation temperature | 1.8MPa,Unannealed | °C | 185 | -- |
| 8.0MPa,Unannealed | °C | 140 | -- | |
| Continuous use temperature | --2 | °C | 90.0to110 | -- |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | TD | % | 0.50 | -- |
| MD | % | 0.10 | -- | |
| Water absorption rate | Saturation,23°C | % | 7.0 | -- |
| Equilibrium,23°C,50%RH | % | 2.0 | -- | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | ohms | -- | 1E+12 | |
| Volume resistivity | ohms·cm | 1E+14 | 1E+12 | |
| Dielectric strength | kV/mm | 29 | 23 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.