Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTMD792,ISO1183 | 1.33到1.35 g/cm³ |
melt mass-flow rate | | ASTMD1238,ISO1133 | 12 g/10min |
Shrinkage rate | | ASTMD955 | 0.30到0.50 % |
Water absorption rate | | ASTMD570,ISO62 | 0.080 % |
Water absorption rate | Saturation | ASTMD570 | 0.25 % |
Water absorption rate | | ISO62 | 0.25 % |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL94 | V-1 |
Hot filament ignition temperature | | IEC60695-2-13 | 960 °C |
Limiting Oxygen Index | | ASTMD2863 | 31 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of simply supported beam without notch | | ISO179,ASTMD256 | 42 kJ/m² |
Impact strength of cantilever beam gap | | ASTMD256,ISO180 | 130 J/m |
Charpy Notched Impact Strength | | ISO179,ASTMD256 | 9.0 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ASTMD638,ISO527-2 | 6000 MPa |
tensile strength | Break | ASTMD638,ISO527-2 | 90.0 MPa |
elongation | Break | ASTMD638,ISO527-2 | 4.0 % |
Flexural modulus | | ASTMD790,ISO178 | 5500 MPa |
Bending stress | | ISO178 | 145 MPa |
Bending stress | | ISO178 | 155 MPa |
Bending stress | Yield | ASTMD790 | 155 MPa |
Bending stress | Break | ASTMD790 | 145 MPa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
CTI | | IEC60112 | 175 V |
Volume resistivity | | ASTMD257 | >1.0E+16 ohms·cm |
dielectric strength | | ASTMD149 | 22 kV/mm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ASTMD648,ISO75-2/A | 142 °C |
Continuous use temperature | | UL746B | 80.0 °C |
Continuous use temperature | | IEC60216 | 135 °C |
vicat | | ISO306/A50,ASTMD15257 | 153 °C |
BallPressure Test | | VDE0470 | 通过 |
| | ASTMD696 | 3E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.