Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 1.35 g/cm³ |
Shrinkage rate | | ASTM D955 | 1.0to1.2 % |
hardness | Test Condition | Test Method | Test Result |
---|
Shore hardness | | ASTM D2240 | 69 |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | HB |
UL flame retardant rating | | UL 94 | HB |
Limiting Oxygen Index | | ASTM D2863 | 24 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | Break | ASTM D638 | 14.3 MPa |
elongation | Break | ASTM D638 | 230 % |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Hot wire ignition (HWI) | | UL 746 | PLC 1 |
Compared to the Leakage Tracking Index (CTI) | | UL 746 | PLC 0 |
High arc combustion index (HAI) | | UL 746 | PLC 1 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Continuous use temperature | | ASTM D794 | 60.0 °C |
brittle temperature | | ASTM D746 | -20.0 °C |
RTI Elec | | UL 746 | 90.0 °C |
RTI Elec | | UL 746 | 90.0 °C |
RTI Elec | | UL 746 | 90.0 °C |
RTI | | UL 746 | 80.0 °C |
RTI | | UL 746 | 90.0 °C |
RTI | | UL 746 | 90.0 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.