Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTMD792 | 1.35 g/cm³ |
Shrinkage rate | | ASTMD955 | 1.0到1.2 % |
hardness | Test Condition | Test Method | Test Result |
---|
| | ASTMD2240 | 69 |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL94 | HB |
UL flame retardant rating | | UL94 | HB |
Limiting Oxygen Index | | ASTMD2863 | 24 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | Break | ASTMD638 | 14.3 MPa |
elongation | Break | ASTMD638 | 230 % |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Hot wire ignition (HWI) | | UL746 | PLC 1 |
Compared to the Leakage Tracking Index (CTI) | | UL746 | PLC 0 |
High arc combustion index (HAI) | | UL746 | PLC 1 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Continuous use temperature | | ASTMD794 | 60.0 °C |
brittle temperature | | ASTMD746 | -20.0 °C |
RTI Elec | | UL746 | 90.0 °C |
RTI Elec | | UL746 | 90.0 °C |
RTI Elec | | UL746 | 90.0 °C |
RTI | | UL746 | 80.0 °C |
RTI | | UL746 | 90.0 °C |
RTI | | UL746 | 90.0 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.