| other | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| characteristic | 高刚性 | |||
| Other performance | Test Condition | Test Method | Test Result | Test Unit |
| Extreme Oxygen Index | 干 | ASTM D-2863 | 23 | % |
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of simply supported beam without notch | ISO 179 | 72 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.75mm | UL 94 | HB | |
| Extreme Oxygen Index | ASTM D2863 | 23 | % | |
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 湿 | 1.7 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | 23°C | ISO 178 | 275 | Mpa |
| Taber abraser | 1000Cycles | ASTM D1044 | -- | mg |
| Elongation at Break | 干(湿) | ASTM D-638 | 3(5) | % |
| Rockwell hardness | 干(湿) | ASTM D-785 | 120(112) | R scale |
| Impact strength of cantilever beam gap | 干(湿) | ASTM D-256 | 127(147) | J/m |
| flexural coefficient | 干(湿) | ASTM D-790 | 9.3(6.3) | GPa |
| Rockwell hardness | 干(湿) | ASTM D-785 | 96(75) | M Scale |
| bending strength | 干(湿) | ASTM D-790 | 289(216) | Mpa |
| tensile strength | 干(湿) | ASTM D-638 | 186(132) | Mpa |
| Tensile modulus | 23°C | ISO 527-2 | 10000 | Mpa |
| tensile strength | ASTM D638 | 186 | Mpa | |
| Break,23°C | ISO 527-2 | 190 | Mpa | |
| elongation | Break | ASTM D638 | 3.0 | % |
| Tensile strain | Break,23°C | ISO 527-2 | 3.0 | % |
| Bending modulus | ASTM D790 | 9300 | Mpa | |
| 23°C | ISO 178 | 9000 | Mpa | |
| bending strength | ASTM D790 | 289 | Mpa | |
| Rockwell hardness | ASTM D785 | M96 | ||
| Bending modulus | ASTM D790/ISO 178 | 9320(MPa) | kg·cm/cm(J/M)ft·lb/in | |
| bending strength | ASTM D790/ISO 178 | 289(MPa) | kg·cm/cm(J/M)ft·lb/in | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa,Unannealed | ASTM D648 | 260 | °C |
| 0.45MPa,Unannealed | ISO 75-2/B | 265 | °C | |
| 1.8MPa,Unannealed | ASTM D648 | 250 | °C | |
| 1.8MPa,Unannealed | ISO 75-2/A | 250 | °C | |
| Linear coefficient of thermal expansion | MD | ASTM D696 | 3E-05 | cm/cm/°C |
| specific heat | 1590 | J/kg/°C | ||
| thermal conductivity | 0.30 | W/m/K | ||
| Hot deformation temperature | 0.46MPa,干 | ASTM D-648 | 260 | °C |
| specific heat | 干 | 1590 | J/(kg.k) | |
| thermal conductivity | 干 | 0.3 | W/(m.K) | |
| Hot deformation temperature | 1.82MPa,干 | ASTM D-648 | 250 | °C |
| UL flame retardant rating | 干 | UL 94 | HB | |
| Linear coefficient of thermal expansion | 干 | ASTM D-696 | 3 | ×10-5/K |
| Combustibility (rate) | UL 94 | HB | ||
| Hot deformation temperature | HDT | ASTM D648/ISO 75 | 250 | ℃(℉) |
| Linear coefficient of thermal expansion | ASTM D696/ISO 11359 | 3 | mm/mm.℃ | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | TD | Internal Method | 0.90 | % |
| MD | Internal Method | 0.40 | % | |
| 干 | 旭化成方法 | 0.4/0.9 | % | |
| Wear factor | 湿 | ASTM D-1044 | 15 | ×10-6kg/1000times |
| Shrinkage rate | 吸水率(Saturation,23°C) | Internal Method | -- | % |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | -- | % |
| density | ASTM D792/ISO 1183 | 1.39 | ||
| Shrinkage rate | ASTM D955 | 0.4-0.9 | % | |
| Water absorption rate | ASTM D570/ISO 62 | 1.7 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric strength | ASTM D149 | 28 | KV/mm | |
| IEC 60243-1 | 28 | KV/mm | ||
| Compared to the anti leakage trace index | 3.00mm | IEC 60112 | PLC 0 | |
| Surface resistivity | ASTM D257 | 1E+15 | ohms | |
| IEC 60093 | 1E+15 | ohms | ||
| Volume resistivity | ASTM D257 | 1E+15 | ohms·cm | |
| 23°C | IEC 60093 | 1E+15 | ohms·cm | |
| Arc resistance | ASTM D495/IEC 60112 | 124 | ||
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | M-Sale | ASTM D785 | 96 | |
| R-Sale | ASTM D785 | 120 | ||
| M-Sale | ISO 2039-2 | 96 | ||
| R-Sale | ISO 2039-2 | 120 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.