Form:Granules | Grade:Extrusion grade
Properties:
Low temperature resistanc
Typical Applications:
filmWire and cable
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | film | Wire and cable |
| Properties: | Low temperature resistanc |
Certificates

Technical Data Sheet
| machinability | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Mold temperature | 20-30 | °C | ||
| Processing temperature | 190-200 | °C | ||
| 185-190 | °C | |||
| 185-195 | °C | |||
| 155-175 | °C | |||
| Dry conditions | 90℃ 2-3小时 | |||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Resilience | ASTM D2630/ISO 4662 | 39 | % | |
| Shore hardness | ASTM D2240/ISO 868 | 90+-2 | Shore A | |
| tear strength | ASTM D624/ISO 34 | 130 | n/mm² | |
| tensile strength | ASTM D412/ISO 527 | 43 | Mpa/Psi | |
| Tensile modulus | 300% | ASTM D412/ISO 527 | 17 | Mpa/Psi |
| 100% | ASTM D412/ISO 527 | 8 | Mpa/Psi | |
| Friction coefficient | DIN 53516 | 35 | mg | |
| Resilience | ISO 4662 | 39 | % | |
| tear strength | ISP 34-1:2004(E) | 130 | kN/m | |
| elongation | Break | ISO 37 | 500 | % |
| tensile strength | ISO 37 | 43 | Mpa | |
| Tensile stress | 300%伸长率 | ISO 37 | 17 | Mpa |
| 100%伸长率 | ISO 37:2005(E) | 8.0 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | ASTM D1525/ISO R306 | 115 | ℃(℉) | |
| Glass transition temperature | ASTM D3418/ISO 815 | -35 | ℃(℉) | |
| Glass transition temperature (Tg) | ASTM D3417 | -35 | °C | |
| Vicat softening temperature | ISO 306 | 115 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D792/ISO 2781/JIS K7311 | 1.2 | ||
| Shore hardness | ISO 868:2006(E) | 90±2/- |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.