PPS DIC.PPS Z-200-E5 DIC Corporation
Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| tensile strength | 23°C | ASTM D638 | 70 | MPa |
| Elongation at Break | 23°C | ASTM D638 | 50 | % |
| Friction coefficient | 动态 | ASTM D3702 | 0.35 | |
| 静态 | ASTM D3702 | 0.36 | ||
| Tensile modulus | 23°C | ASTM D638 | 3100 | MPa |
| 泊松比 | ASTME132 | 0.38 | ||
| bending strength | 23°C | ASTM D790 | 110 | MPa |
| Bending modulus | 23°C | ASTM D790 | 2900 | MPa |
| Impact strength of cantilever beam gap | 23°C | ASTM D256 | 80 | J/m |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPaUnannealed | ASTM D648 | 160 | °C |
| 1.80MPaUnannealed | ASTM D648 | 105 | °C | |
| Linear coefficient of thermal expansion | MD | ASTM D696 | 4.5E-05 | cm/cm/°C |
| TD | ASTM D696 | 4.5E-05 | cm/cm/°C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | (23°C,24hr) | ASTM D570 | 0.03 | % |
| density | ASTM D792 | 1.32 | g/cm³ | |
| Shrinkage rate | MD | ASTM D995 | 1.30 | % |
| TD | ASTM D995 | 1.50 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | ASTM D257 | 1E+16 | Ω.cm | |
| Dielectric strength | 1.60mm | ASTM D149 | 16 | KV/mm |
| Dielectric constant | 23°C | ASTM D150 | 3.4 | 1MHz |
| Dissipation factor | 23°C | ASTM D150 | 2E-03 | 1MHz |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | ASTM D785 | 118 | R | |
| flame retardant performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL -94 | V-0 | 0.75mm | |
| UL -94 | V-0 | 3.00mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.