PC Makrolon® 9417 704292
146
- Properties:Flame retardantHigh mobilityFiller: Glass fiber reinf10% filler by weight10% filler by weight
- Usages:Automotive ApplicationsLighting installationelectrical equipment
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Water absorption rate | ISO 62 | 0.10 % | |
Shrinkage rate | ISO 294-4 | 0.60 % | |
Water absorption rate | ISO 62 | 0.26 % | |
Shrinkage rate | ISO 294-4 | 0.45 % | |
ISO 2577 | 0.40-0.60 % | ||
ISO 2577 | 0.40-0.60 % | ||
Melt volume flow rate | ISO 1133 | 6.00 cm3/10min | |
melt mass-flow rate | ISO 1133 | 7.0 g/10min | |
Apparent density | ISO 60 | 0.64 g/cm³ | |
density | ISO 1183 | 1.27 g/cm³ |
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
ball-indentation hardness | ISO 2039-1 | 128 Mpa |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
FlashIgnitionTemperature | ASTM D1929 | 470 °C | |
SelfIgnitionTemperature | ASTM D1929 | 550 °C | |
UL flame retardant rating | UL 94 | V-0 | |
UL 94 | 5VA | ||
UL 94 | 5VA | ||
Burning wire flammability index | IEC 60695-2-12 | 960 °C | |
IEC 60695-2-12 | 960 °C | ||
IEC 60695-2-12 | 960 °C | ||
Hot filament ignition temperature | IEC 60695-2-13 | 825 °C | |
IEC 60695-2-13 | 900 °C | ||
IEC 60695-2-13 | 900 °C | ||
Limiting Oxygen Index | ISO 4589-2 | 35 % | |
ApplicationofFlamefromSmallBurner-Method | DIN 53438-1,-3 | K1.F1 | |
Burning rate - US-FMVSS | ISO 3795 | passed |
Supplementary Information | Test Condition | Test Method | Test Result |
---|---|---|---|
electrolytic corrosion | IEC 60426 | A1 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile creep modulus | ISO 899-1 | 3600 Mpa | |
Tensile strain | ISO 527-2/5 | 15 % | |
ISO 527-2/5 | 4.6 % | ||
tensile strength | ISO 527-2/5 | 64.0 Mpa | |
ISO 527-2/5 | 45.0 Mpa | ||
Tensile modulus | ISO 527-2/1 | 3800 Mpa | |
Tensile creep modulus | ISO 899-1 | 2900 Mpa | |
Flexural modulus | ISO 178 | 3600 Mpa | |
Bending Strain | ISO 178 | 5.8 % | |
bending strength | ISO 178 | 105 Mpa | |
ISO 178 | 95.0 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Multi axis Instrumented Impact Energy | ISO 6603-2 | 25.0 J | |
Multi axis Instrumented Peak Impact Force | ISO 6603-2 | 3700 N | |
ISO 6603-2 | 4000 N | ||
Charpy Notched Impact Strength | ISO 7391 | 10 kJ/m² | |
Impact strength of simply supported beam without notch | ISO 179/1eU | 150 kJ/m² | |
ISO 179/1eU | 120 kJ/m² | ||
Multi axis Instrumented Impact Energy | ISO 6603-2 | 15.0 J | |
Impact strength of cantilever beam gap | ISO 7391 | 10 kJ/m² | |
Impact strength of simply supported beam without notch | ISO 179/1eU | 100 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Dissipation Factor | IEC 60250 | 1E-03 | |
IEC 60250 | 9E-03 | ||
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | V | |
IEC 60112 | V | ||
relative permittivity | IEC 60250 | 3.20 | |
IEC 60250 | 3.20 | ||
dielectric strength | IEC 60243-1 | 36 KV/mm | |
Volume resistivity | IEC 60093 | 1E+16 ohms·cm | |
Surface Resistivity | IEC 60093 | 1E+16 ohms |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
RTI Str | UL 746 | 125 °C | |
RTI Imp | UL 746 | 115 °C | |
RTI Elec | UL 746 | 125 °C | |
thermal conductivity | ISO 8302 | 0.22 W/m/K | |
Linear coefficient of thermal expansion | ISO 11359-2 | 6.5E-05 cm/cm/°C | |
Heat distortion temperature | ISO 75-2/B | 141 °C | |
ISO 75-2/A | 135 °C | ||
vicat | ISO 306/B50 | 143 °C | |
ISO 306/B120 | 144 °C | ||
ball-indentation hardness | IEC 60695-10-2 | Pass | |
Linear coefficient of thermal expansion | ISO 11359-2 | 4E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.