PC Makrolon®  9417 704292

146
  • Properties:
    Flame retardant
    High mobility
    Filler: Glass fiber reinf
    10% filler by weight
    10% filler by weight
  • Usages:
    Automotive Applications
    Lighting installation
    electrical equipment

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
Water absorption rateISO 620.10 %
Shrinkage rateISO 294-40.60 %
Water absorption rateISO 620.26 %
Shrinkage rateISO 294-40.45 %
Shrinkage rateISO 25770.40-0.60 %
Shrinkage rateISO 25770.40-0.60 %
Melt volume flow rateISO 11336.00 cm3/10min
melt mass-flow rateISO 11337.0 g/10min
Apparent densityISO 600.64 g/cm³
densityISO 11831.27 g/cm³
hardnessTest ConditionTest MethodTest Result
ball-indentation hardnessISO 2039-1128 Mpa
flammabilityTest ConditionTest MethodTest Result
FlashIgnitionTemperatureASTM D1929470 °C
SelfIgnitionTemperatureASTM D1929550 °C
UL flame retardant ratingUL 94V-0
UL flame retardant ratingUL 945VA
UL flame retardant ratingUL 945VA
Burning wire flammability indexIEC 60695-2-12960 °C
Burning wire flammability indexIEC 60695-2-12960 °C
Burning wire flammability indexIEC 60695-2-12960 °C
Hot filament ignition temperatureIEC 60695-2-13825 °C
Hot filament ignition temperatureIEC 60695-2-13900 °C
Hot filament ignition temperatureIEC 60695-2-13900 °C
Limiting Oxygen IndexISO 4589-235 %
ApplicationofFlamefromSmallBurner-MethodDIN 53438-1,-3K1.F1
Burning rate - US-FMVSSISO 3795passed
Supplementary InformationTest ConditionTest MethodTest Result
electrolytic corrosionIEC 60426A1
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile creep modulusISO 899-13600 Mpa
Tensile strainISO 527-2/515 %
Tensile strainISO 527-2/54.6 %
tensile strength ISO 527-2/564.0 Mpa
tensile strength ISO 527-2/545.0 Mpa
Tensile modulusISO 527-2/13800 Mpa
Tensile creep modulusISO 899-12900 Mpa
Flexural modulusISO 1783600 Mpa
Bending StrainISO 1785.8 %
bending strengthISO 178105 Mpa
bending strengthISO 17895.0 Mpa
Impact resistanceTest ConditionTest MethodTest Result
Multi axis Instrumented Impact EnergyISO 6603-225.0 J
Multi axis Instrumented Peak Impact ForceISO 6603-23700 N
Multi axis Instrumented Peak Impact ForceISO 6603-24000 N
Charpy Notched Impact StrengthISO 739110 kJ/m²
Impact strength of simply supported beam without notchISO 179/1eU150 kJ/m²
Impact strength of simply supported beam without notchISO 179/1eU120 kJ/m²
Multi axis Instrumented Impact EnergyISO 6603-215.0 J
Impact strength of cantilever beam gapISO 739110 kJ/m²
Impact strength of simply supported beam without notchISO 179/1eU100 kJ/m²
Electrical performanceTest ConditionTest MethodTest Result
Dissipation FactorIEC 602501E-03
Dissipation FactorIEC 602509E-03
Compared to the Leakage Tracking Index (CTI)IEC 60112 V
Compared to the Leakage Tracking Index (CTI)IEC 60112 V
relative permittivityIEC 602503.20
relative permittivityIEC 602503.20
dielectric strengthIEC 60243-136 KV/mm
Volume resistivityIEC 600931E+16 ohms·cm
Surface ResistivityIEC 600931E+16 ohms
Thermal performanceTest ConditionTest MethodTest Result
RTI StrUL 746125 °C
RTI ImpUL 746115 °C
RTI ElecUL 746125 °C
thermal conductivityISO 83020.22 W/m/K
Linear coefficient of thermal expansionISO 11359-26.5E-05 cm/cm/°C
Heat distortion temperatureISO 75-2/B141 °C
Heat distortion temperatureISO 75-2/A135 °C
vicatISO 306/B50143 °C
vicatISO 306/B120144 °C
ball-indentation hardnessIEC 60695-10-2Pass
Linear coefficient of thermal expansionISO 11359-24E-05 cm/cm/°C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.

Contact Us

Get App

Top