Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ISO 1183 | 1.35 g/cm³ |
hardness | Test Condition | Test Method | Test Result |
---|
ball-indentation hardness | | ISO 2039-1 | 170 MPa |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO 527-2 | 7000 MPa |
tensile strength | Yield | ISO 527-2 | 80.0 MPa |
tensile strength | Break | ISO 527-2 | 100to130 MPa |
compression stress | | ISO 604 | 170 MPa |
coefficient of friction | | ASTM D1894 | 0.020 |
coefficient of friction | | ASTM D1894 | 0.020 |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ISO 180 | 15 kJ/m² |
Suspended wall beam without notch impact strength | | ISO 180 | 30 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | IEC 60093 | 1E+08 ohms |
dielectric constant | | IEC 60250 | 5.00 |
Dissipation Factor | | IEC 60250 | 0.30 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Linear coefficient of thermal expansion | | ISO 11359-2 | 3E-05 cm/cm/°C |
thermal conductivity | | ISO 8302 | 0.29 W/m/K |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.