PA12 4533 SA01 MED ARKEMA FRANCE
43
Form:Granules | Grade:Medical grade
Properties:
Low wear
Typical Applications:
Medical and nursing supplies
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Medical and nursing supplies |
| Properties: | Low wear |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | -- | |
| 23°C | ISO 179/1eU | -- | ||
| squeeze out | Test Condition | Test Method | Test Result | Test Unit |
| Melt Temperature | 210 to 230 | °C | ||
| drying time | 4.0 to 6.0 | hr | ||
| drying temperature | 60 to 70 | °C | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2 | 88.0 | Mpa | |
| tensile strength | 50% Strain | ISO 527-2 | 9.00 | Mpa |
| Tensile strain | Break | ISO 527-2 | > 50 | % |
| injection | Test Condition | Test Method | Test Result | Test Unit |
| Mold temperature | 10 to 30 | °C | ||
| Processing (melt) temperature | 200 to 270 | °C | ||
| drying time | 4.0 to 6.0 | hr | ||
| drying temperature | 60 to 70 | °C | ||
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | ISO 306/B50 | 111 | °C | |
| Melting temperature | ISO 11357-3 | 147 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium, 23°C, 50% RH | ISO 62 | 0.40 | % |
| Saturation, 23°C | ISO 62 | 1.2 | % | |
| Shrinkage rate | Flow | ISO 294-4 | 1.1 | % |
| 横向Flow | ISO 294-4 | 0.40 | % | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Shore hardness | Shore A, 3 Sec | ISO 7619-1 | 92 | |
| Shore D, 15 Sec | ISO 7619-1 | 41 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.