plas
Log In

PVC Aurora PVC AP2261 UK Aurora Plastics

0

Technical Data Sheet

impact performanceTest ConditionTest MethodTest Result
Dart impact22°C,Extrudedat380to390°Fmelttemperature3ASTM D4226178 J/cm
Dart impact22°C,Extrudedat380to390°Fmelttemperature2ASTM D422680.1 J/cm
Impact strength of cantilever beam gap22°CASTM D256280 J/m
Dart impact22°C,Extrudedat380to390°Fmelttemperature3ASTM D4226178 J/cm
Impact strength of cantilever beam gap22°CASTM D256280 J/m
Dart impact22°C,Extrudedat380to390°Fmelttemperature2ASTM D422680.1 J/cm
flammabilityTest ConditionTest MethodTest Result
UL flame retardant rating--UL 94V-0
UL flame retardant rating--ASTM D635HB
UL flame retardant rating--UL 94V-0
UL flame retardant rating--ASTM D635HB
mechanical propertiesTest ConditionTest MethodTest Result
bending strength22°CASTM D79079.3 MPa
Bending modulus22°CASTM D7902410 MPa
tensile strengthYield,22°CASTM D63842.1 MPa
Tensile modulus22°CASTM D6382550 MPa
Tensile modulus22°CASTM D6382550 MPa
tensile strengthYield,22°CASTM D63842.1 MPa
Bending modulus22°CASTM D7902410 MPa
bending strength22°CASTM D79079.3 MPa
thermal performanceTest ConditionTest MethodTest Result
Linear coefficient of thermal expansionMD:22°CASTM D6966.3E-05 cm/cm/°C
Linear coefficient of thermal expansionMD:22°CASTM D6966.3E-05 cm/cm/°C
Hot deformation temperature1.8MPa,UnannealedASTM D64871.1 °C
Hot deformation temperature1.8MPa,UnannealedASTM D64871.1 °C
Physical propertiesTest ConditionTest MethodTest Result
PVC unit classificationASTM D178414354
PVC unit classificationASTM D3679Class2
PVC unit classificationASTM D42161-31032-23-0000
densityASTM D7921.38to1.42 g/cm³
PVC unit classificationASTM D178414354
PVC unit classificationASTM D42161-31032-23-0000
densityASTM D7921.38to1.42 g/cm³
PVC unit classificationASTM D3679Class2
hardnessTest ConditionTest MethodTest Result
Shore hardnessShoreD,22°CASTM D224077to83
Shore hardnessShoreD,22°CASTM D224077to83
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.