Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ASTM D570 | 1.52 g/cm3 | |
Water absorption rate | ASTM D570 | 0.09 % | |
Shrinkage rate | ASTM D955 | 0.6-1.1 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
tensile strength | ASTM D638 | 75 MPa | |
elongation | Break | ASTM D638 | 4 % |
bending strength | ASTM D790 | 110 MPa | |
Flexural modulus | ASTM D790 | 4000 MPa | |
Impact strength of cantilever beam gap | ISO 179 | 40 J/m | |
Charpy Notched Impact Strength | ISO 179 | 6 KJ/m2 |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
dielectric strength | ASTM D149 | 20 MV/m | |
dielectric loss tangent | ASTM D150 | 0.02 | |
Volume resistivity | ASTM 257 | 1014 Ω.M | |
dielectric constant | ASTM D150 | 3.2 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
ASTM D648 | 185 ℃ | ||
Flame retardancy | UL94 V-0 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.