ABS 348 INEOS USA
114
Form:Granules
Properties:
High glossMedium impact resistance
Typical Applications:
Medical supplies
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Medical supplies |
| Properties: | High gloss | Medium impact resistance |
Certificates

Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| gloss | 60° | ASTM D523 | 97 | |
| 20° | ASTM D523 | 88 | ||
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of cantilever beam gap | 23°C | ASTM D256 | 290 | J/m |
| -30℃ | ASTM D256 | 110 | J/m | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| elongation | Break, 23°C | ASTM D638 | 25 | % |
| tensile strength | Yield,23°C | ASTM D638 | 44.8 | Mpa |
| Break, 23°C | ASTM D638 | 34.5 | Mpa | |
| Tensile modulus | ASTM D638 | 2480 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | ASTM D15252 | 104 | °C | |
| Hot deformation temperature | 1.8MPa,Annealed | ASTM D648 | 97.2 | °C |
| 0.45MPa,Annealed | ASTM D648 | 100 | °C | |
| Linear coefficient of thermal expansion | MD | ISO 11359-2 | 8.0E-5 to 1.1E-4 | cm/cm/°C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium, 23°C, 50% RH | ISO 62 | 0.22 | % |
| density | ASTM D792 | 1.04 | g/cm³ | |
| melt mass-flow rate | 220°C/10.0kg | ASTM D1238 | 19 | cm3/10min |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.