Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 1.53 g/cm³ |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | | ASTM D638 | 210 MPa |
elongation at break | | ASTM D638 | 2.0 % |
Flexural modulus | | ASTM D790 | 14000 MPa |
Impact strength of cantilever beam gap | | ASTM D256 | 192 J/m |
Flame retardant performance | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL -94 | HB - |
GWIT | | IEC 60695-2-12 | 650 °C |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | ASTM D257 | 1E+13 Ω.cm |
Volume resistivity | | ASTM D257 | 1E+15 Ω.cm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ASTM D648 | 212 °C |
Heat distortion temperature | | ASTM D648 | 195 °C |
vicat | | ASTM1525 | 215 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.