Share
Add to compare

PA6 B50H1 SOLVAY SHANGHAI

49

Form:Granules | Grade:Flame retardant grade

Properties:
High rigidityThermal stability
Typical Applications:
Laptop caseElectronic fieldElectrical fieldPipe fittingscurrencypipelineProfile
Product Description
Certificates(0)
Datasheet

Product Description

Typical Applications:Laptop case | Electronic field | Electrical field | Pipe fittings | currency | pipeline | Profile
Properties:High rigidity | Thermal stability

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of simply supported beam without notch-30°CISO 179/1eU80kJ/m²
Impact strength of simply supported beam without notch23°CISO 179/1eU70kJ/m²
flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant rating0.40mmUL 94V-0
UL flame retardant rating0.8mmUL 94V-0
UL flame retardant rating1.6mmUL 94V-0
UL flame retardant rating3.2mmUL 94V-0
Burning wire flammability index0.8mmIEC 60695-2-12960°C
Burning wire flammability index1.6mmIEC 60695-2-12960°C
Burning wire flammability index3.2mmIEC 60695-2-12960°C
Ignition temperature of heating wire1.6mmIEC 60695-2-13650°C
Extreme Oxygen IndexISO 4589-233%
UL flame retardant ratingNFF16-101F2
smoke densityNFF16-101I2
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Tensile modulus23°CISO 527-2/1A3750Mpa
tensile strengthYield,23°CASTM D63885.0Mpa
tensile strengthYield,23°CISO 527-2/1A80.0Mpa
tensile strengthBreak,23°CISO 527-2/1A70.0Mpa
Tensile strainYield,23°CISO 527-24.0%
elongationBreak,23°CASTM D63815%
Tensile strainBreak,23°CISO 527-212%
Bending modulus23°CASTM D7903800Mpa
Bending modulus23°CISO 1783700Mpa
bending strength23°CASTM D790125Mpa
bending strength23°CISO 178130Mpa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature1.8MPa,UnannealedASTM D64885.0°C
Hot deformation temperature1.8MPa,UnannealedISO 75-2/Af85.0°C
Melting temperatureISO 11357-3242°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Water absorption rate23°C,24hrISO 621.1%
Water absorption rateEquilibrium,23°C,50%RHISO 623.1%
Outdoor applicabilityUL 746Cf1
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Compared to the anti leakage trace indexSolutionAIEC 60112PLC 0
Surface resistivityIEC 600931E+15ohms
Volume resistivityIEC 600931E+15ohms·cm
Dielectric strength0.800mmIEC 60243-133KV/mm
Relative permittivityIEC 602503.60
Dissipation factorIEC 602500.020
Supplementary InformationTest ConditionTest MethodTest ResultTest Unit
EuropeanRailwaysCertificationsR22EN45545-2HL2
EuropeanRailwaysCertificationsR23EN45545-2HL3
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.