| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Huangdu Index | ASTM D1925 | -3.3 | YI | |
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of cantilever beam gap | 23°C | ISO 180 | 4.0 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL 94 | V-2 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | 23°C | ISO 178 | 2700 | Mpa |
| bending strength | 23°C | ISO 178 | 100 | Mpa |
| Nominal tensile fracture strain | 23°C | ISO 527-2 | 25 | % |
| tensile strength | Yield,23°C | ISO 527-2 | 86.0 | Mpa |
| Tensile modulus | 23°C | ISO 527-2 | 3100 | Mpa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | ISO 11357-3 | 260 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 70.0 | °C |
| 0.45MPa,Unannealed | ISO 75-2/B | 200 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Relative viscosity | ISO 307 | 2.7 | ||
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 15512 | 0.30 | % |
| Shrinkage rate | MD | ISO 294-4 | 1.4 | % |
| TD | ISO 294-4 | 1.4 | % | |
| density | ISO 1183 | 1.14 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | 3.00mm | IEC 60112 | PLC 0 | |
| Dielectric strength | 1.00mm | IEC 60243-1 | 32 | KV/mm |
| Volume resistivity | 2.00mm | IEC 60093 | 1E+14 | ohms·cm |
| Surface resistivity | IEC 60093 | 1E+12 | ohms | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Sale,23°C | ISO 2039-2 | 120 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.