Share
Add to Compare

PP Homopolymer POLYFLAM® RPP 2000 S A SCHULMAN USA

Typical Applications:
Seats outdoor applications
Product Description
Certificates(0)
Datasheet

Product Description

Typical Applications:Seats | outdoor applications

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of simply supported beam without notch23°CISO 179/1eUNoBreak
Charpy Notched Impact Strength23°CISO 179/1eA5.0kJ/m²
flammabilityTest ConditionTest MethodTest ResultTest Unit
Burning wire flammability index0.75mmIEC 60695-2-12960°C
Burning wire flammability index1.5mmIEC 60695-2-12960°C
Burning wire flammability index3.0mmIEC 60695-2-12960°C
Hot filament ignition temperature0.75mmIEC 60695-2-13775°C
Hot filament ignition temperature1.5mmIEC 60695-2-13775°C
Hot filament ignition temperature3.0mmIEC 60695-2-13775°C
Extreme Oxygen IndexISO 4589-226%
UL flame retardant rating0.8mmIEC 60695-11-10,-20V-2
UL flame retardant rating1.6mmIEC 60695-11-10,-20V-2
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Tensile modulusISO 527-2/1A/11100MPa
tensile strengthYieldISO 527-2/1A/5032.0MPa
Tensile strainYieldISO 527-2/1A/5011%
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature1.8MPa,UnannealedISO 75-2/Af49.0°C
Vicat softening temperature--ISO 306/A120151°C
Vicat softening temperature--ISO 306/B5090.0°C
Ball Pressure Test140°CIEC 60695-10-2Pass
Hot deformation temperature0.45MPa,UnannealedISO 75-2/Bf94.0°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
densityISO 1183/A0.910g/cm³
Melt Volume Flow Rate (MVR)230°C/2.16kgISO 11337.00cm³/10min
Water absorption rate23°C,24hrISO 620.16%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Surface resistivityIEC 60093>1.0E+15ohms
Volume resistivityIEC 60093>1.0E+13ohms·cm
Compared to the anti leakage trace indexIEC 60112PLC 0
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.