PC DX09301C SABIC INNOVATIVE US
71
Form:Granules | Grade:Injection grade
Properties:
Thermal stabilityLow temperature resistanc
Typical Applications:
Automotive componentsElectronic and electrical accessories
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive components | Electronic and electrical accessories |
| Properties: | Thermal stability | Low temperature resistanc |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Dart impact | 23°C,EnergyatPeakLoad | ASTM D3763 | 8.18 | J |
| 23°C | ISO 180/1U | 200 | kJ/m² | |
| ASTM D4812 | 2200 | J/m | ||
| ISO 180/1A | 4.6 | kJ/m² | ||
| ASTM D256 | 53 | J/m | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Fracture, 50.0mm span | ASTM D790 | 101 | Mpa | |
| --8 | ISO 178 | 99.0 | Mpa | |
| --7 | ISO 178 | 2560 | Mpa | |
| 50.0mm span | ASTM D790 | 2600 | Mpa | |
| crack | ISO 527-2/5 | 12 | % | |
| ASTM D638 | 15 | % | ||
| yield | ISO 527-2/5 | 3.1 | % | |
| ASTM D638 | 5.4 | % | ||
| crack | ISO 527-2/5 | 54.0 | Mpa | |
| ASTM D638 | 51.7 | Mpa | ||
| yield | ISO 527-2/5 | 66.0 | Mpa | |
| ASTM D638 | 64.9 | Mpa | ||
| --1 | ASTM D638 | 2680 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| 1.8MPa, unannealed, 64.0mm span of | ISO 75-2/Af | 137 | °C | |
| 1.8MPa, unannealed, 3.20mm | ASTM D648 | 138 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | TD:24hr | ASTM D955 | 0.50-0.70 | % |
| MD:24hr | ASTM D955 | 0.50-0.70 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| StaticDecay | FTMS101B | 0.1 | sec | |
| Volume resistivity | ASTM D257 | 1.0E+3-1.0E+7 | ohms·cm | |
| Surface resistivity | ASTM D257 | 1.0E+3-1.0E+7 | ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.