Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| Other performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| UL flame retardant rating | UL 94 | HB | ||
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | ISO 294-4 | 1.3 | % | |
| Water absorption rate | 23°C/50%RH | ISO 62 | 2.6 | % |
| density | ISO 1183 | 1.41 | g/cm³ | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Charpy Notched Impact Strength | 23°C | ISO 180-1A | 21 | kJ/m² |
| Impact strength of cantilever beam gap | 23°C | ISO 180-1A | 21 | kJ/m² |
| tensile strength | 120°C | ISO 527-2 | 110 | Mpa |
| 160°C | ISO 527-2 | 100 | Mpa | |
| Tensile modulus | 120°C | ISO 527-2 | 5500 | Mpa |
| 160°C | ISO 527-2 | 5000 | Mpa | |
| Bending modulus | 120°C | ISO 178 | 4700 | Mpa |
| 160°C | ISO 178 | 3900 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | ISO 3146 | 295 | °C | |
| Hot deformation temperature | 1.8MPa | ISO 75-1 | 290 | °C |
| Linear coefficient of thermal expansion | ISO 11359-2 | 0.00002 | cm/cm/°C | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | IEC 60093 | 1E+11 | ohm*cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.