PA6 LUBEMID B27 GF25 NATURAL
0
- Properties:Fillerglass fiber reinforced material25%filler by weight
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ISO 1183/A | 1.29to1.33 g/cm³ |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
Burning wire flammability index | IEC 60695-2-12 | 650 °C |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ISO 527-2/1A/1 | 7500to8000 MPa | |
tensile strength | Yield | ISO 527-2/1A/5 | 125to135 MPa |
Break | ISO 527-2/1A/5 | 125to135 MPa | |
Tensile strain | Yield | ISO 527-2/1A/5 | 2.0to3.0 % |
Break | ISO 527-2/1A/5 | 2.0to3.0 % | |
Flexural modulus | ISO 178 | 7000to7500 MPa | |
bending strength | ISO 178 | 165to175 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of cantilever beam gap | ASTM D256 | 60to70 kJ/m² | |
ASTM D256 | 8.0to9.0 kJ/m² | ||
ISO 180/A | 7.0to8.0 kJ/m² | ||
Suspended wall beam without notch impact strength | ISO 180 | 50to60 kJ/m² | |
Charpy Notched Impact Strength | ISO 179/1eA | 7.0to8.0 kJ/m² | |
Impact strength of simply supported beam without notch | ISO 179/1eU | 50to60 kJ/m² | |
Impact strength of cantilever beam gap | ASTM D256A | 80to90 J/m |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ASTM D648 | 210to220 °C | |
ISO 75-2/B | 215to225 °C | ||
ASTM D648 | 200to210 °C | ||
vicat | ISO 306/A120 | 210to220 °C | |
ISO 306/B120 | 205to215 °C | ||
melting temperature | 内部方法 | 210to225 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.