Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | ISO 62 | 0.20 % |
density | | ISO 1183 | 1.13 g/cm³ |
flammability | Test Condition | Test Method | Test Result |
---|
Hot filament ignition temperature | | IEC 60695-2-13 | 650 °C |
UL flame retardant rating | | UL 94 | HB |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ISO 180/1A | 40 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile strain | | ISO 527-2/5 | 50 % |
tensile strength | | ISO 527-2/5 | 45.0 MPa |
Tensile modulus | | ISO 527-2/5 | 2250 MPa |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ISO 75-2/B | 120 °C |
vicat | | ISO 306/B | 115 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.