PCT TE3002 CELANESE USA
0
- Properties:Flame retardant performance glass fiber reinforced material 30% filler by weight
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 7.0 kJ/m² |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 20 kJ/m² |
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| UL flame retardant rating | 0.8mm | UL 94 | V-0 |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Tensile modulus | ISO 527-2/1A/1 | 10000 MPa | |
| tensile strength | Break | ISO 527-2/1A/5 | 100 MPa |
| Tensile strain | Break | ISO 527-2/1A/5 | 1.2 % |
| Bending modulus | 23°C | ISO 178 | 10500 MPa |
| bending strength | 23°C | ISO 178 | 150 MPa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 240 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Tensile strain | Break | ISO 527-2/1A/5 | 1.2 % |
| Bending modulus | 23℃ | ISO 178 | 10500 MPa |
| bending strength | 23℃ | ISO 178 | 150 MPa |
| Charpy Notched Impact Strength | 23℃ | ISO 179/1eA | 7.0 kJ/m2 |
| 简支梁Notched冲击强度,23℃ | ISO 179/1eU | 20 kJ/m2 | |
| density | ISO 1183 | 1.65 g/cm³ | |
| ISO 1183 | 1.65 g/cm3 | ||
| Tensile modulus | ISO 527-2/1A/1 | 10000 MPa | |
| tensile strength | Break | ISO 527-2/1A/5 | 100 MPa |
| Charpy Notched Impact Strength | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Charpy Notched Impact Strength | 可燃性,UL 阻燃等级 | UL 94 | V-0 0.790 mm |
| Thermal Properties | 热变形温度,1.8 MPa, Unannealed | ISO 75-2/A | 240 ℃ |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.