POM F20-03 KEP KOREA
256
Form:Granules | Grade:Injection grade
Properties:
Thermal stabilitywear resistantHigh temperature resistancurrency
Typical Applications:
Thermal stabilitywear resistantHigh temperature resistancecurrency
Product Description
Certificates(3)
Datasheet
Alternative(16)
Product Description
| Typical Applications: | Thermal stability | wear resistant | High temperature resistance | currency |
| Properties: | Thermal stability | wear resistant | High temperature resistan | currency |
Certificates


Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | -30°C | ISO 179/1eA | 5.5 | kJ/m² |
| 23°C | ISO 179/1eA | 6.5 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL 94 | HB | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2 | 2750 | Mpa | |
| tensile strength | ISO 527-2 | 65.0 | Mpa | |
| Tensile strain | Yield | ISO 527-2 | 10 | % |
| Break | ISO 527-2 | 35 | % | |
| Bending modulus | ISO 178 | 2550 | Mpa | |
| bending strength | ISO 178 | 87.0 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 100 | °C |
| Melting temperature | ISO 11357-3 | 165 | °C | |
| Linear coefficient of thermal expansion | MD | ISO 11359-2 | 1.2E-04 | cm/cm/°C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.41 | g/cm³ | |
| melt mass-flow rate | 190°C/2.16kg | ISO 1133 | 9.0 | g/10min |
| Shrinkage rate | MD:3.00mm | Internal Method | 2.0 | % |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.20 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | IEC 60093 | 1E+16 | ohms | |
| Volume resistivity | IEC 60093 | 1E+14 | ohms·cm | |
| Dielectric strength | IEC 60243-1 | 19 | KV/mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.