PA Stanyl® HFX50S DSM Additive Manufacturing

0
  • Properties:
    Filler
    glass fiber reinforced material
    30%
    filler by weight

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
flowmm/mm25.4E-3-134.6E-3
Water absorption rate%0.15-0.53
hardnessTest ConditionTest MethodTest Result
Rockwell hardness122to125
Mechanical propertiesTest ConditionTest MethodTest Result
yield%1.5-5.0
fracture56.0to260.0 Mpa
fracture26.0to260.0 Mpa
fracture%2.0-4.6
fracture%1.7-2.7
yield27.03to260.0 Mpa
Impact resistanceTest ConditionTest MethodTest Result
Suspended wall beam without notch impact strengthJ/m0.085to0.462
Charpy Notched Impact StrengthkJ/m²0.789to3.762
Impact strength of simply supported beam without notchkJ/m²7.892to21.357
Impact strength of cantilever beam gapJ/m0.013to0.050
Electrical performanceTest ConditionTest MethodTest Result
Compared to the Leakage Tracking Index (CTI)VPLC 0
dielectric strengthV/mil490to610
Surface Resistivityohms1.0E+12-1.0E+14
Volume resistivityohms·cm1.0E+4-1.0E+16
Thermal performanceTest ConditionTest MethodTest Result
Linear coefficient of thermal expansionmm/mm/°C30.5E-5到50.8E-5
melting temperature°C220to265
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.