PA66 LUBEMID A26 NATURAL LUBEN PLAST srl
Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 2.5to4.5 | kJ/m² |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 40to60 | kJ/m² |
| Impact strength of cantilever beam gap | 23°C,3.20mm | ASTM D256A | 30to50 | J/m |
| 23°C3 | ASTM D256 | 80to90 | kJ/m² | |
| 23°C4 | ASTM D256 | 3.0to5.0 | kJ/m² | |
| 23°C | ISO 180/A | 2.5to4.5 | kJ/m² | |
| Suspended wall beam without notch impact strength | 23°C | ISO 180 | 50to70 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 3.2mm | UL 94 | V-2 | |
| Burning wire flammability index | 2.0mm | IEC 60695-2-12 | 850 | °C |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | Yield | ISO 527-2/1A/50 | 60.0to65.0 | MPa |
| Break | ISO 527-2/1A/50 | 60.0to65.0 | MPa | |
| Tensile strain | Yield | ISO 527-2/1A/50 | 5.0to8.0 | % |
| Break | ISO 527-2/1A/50 | 5.0to8.0 | % | |
| Bending modulus | ISO 178 | 1800to2300 | MPa | |
| bending strength | ISO 178 | 65.0to70.0 | MPa | |
| Tensile modulus | ISO 527-2/1A/1 | 2500to3000 | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa,Unannealed,3.20mm | ASTM D648 | 215to225 | °C |
| 0.45MPa,Unannealed | ISO 75-2/B | 220to230 | °C | |
| 1.8MPa,Unannealed,3.20mm | ASTM D648 | 70.0to80.0 | °C | |
| Vicat softening temperature | -- | ISO 306/A120 | 240to250 | °C |
| -- | ISO 306/B120 | 230to240 | °C | |
| Melting temperature | Internal Method | 250to265 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183/A | 1.11to1.15 | g/cm³ |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.