Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 3.0 | kJ/m² |
| Suspended wall beam without notch impact strength | 23°C | ISO 180/1U | 25 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.00mm | UL 94 | V-0 | |
| 1.00mm | UL 94 | V-0V-0 | ||
| Burning wire flammability index | 1.00mm | IEC 60695-2-12 | 960 | °C |
| Hot filament ignition temperature | 1.00mm | IEC 60695-2-13 | 800 | °C |
| 1.50mm | IEC 60695-2-13 | 775 | °C | |
| 1.60mm | IEC 60695-2-13 | 775775 | °C | |
| 3.00mm | IEC 60695-2-13 | 800 | °C | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | ISO 178 | 11000 | Mpa | |
| bending strength | ISO 178 | 170 | Mpa | |
| Tensile strain | Break | ISO 527-2/5 | 1.7 | % |
| tensile strength | Break | ISO 527-2/5 | 105 | Mpa |
| Tensile modulus | ISO 527-2/1 | 12000 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| thermal conductivity | --10 | ISO 22007-2 | 1.5 | W/m/K |
| --9 | ISO 22007-2 | 1.31.3 | W/m/K | |
| --8 | ISO 22007-2 | 1.11.1 | W/m/K | |
| --7 | ISO 22007-2 | 0.80 | W/m/K | |
| Horizontal: 23 to 80 ° C | Across Flow, 23to80℃ | ISO 11359-2 | 7.3E-05 | cm/cm/°C |
| Horizontal: -30 to 80 ° C | ISO 11359-2 | 6E-05 | cm/cm/°C | |
| Horizontal: -40 to 40 ° C | Across Flow, -40to40℃ | ASTME831 | 4.8E-54.8E-5 | cm/cm/°C |
| Flow: 23 to 80 ° C | 23to80℃ | ISO 11359-2 | 3.7E-05 | cm/cm/°C |
| Flow: -30 to 80 ° C | ISO 11359-2 | 3.5E-05 | cm/cm/°C | |
| Flow: -40 to 40 ° C | ASTME831 | 3.1E-53.1E-5 | cm/cm/°C | |
| Ball Pressure Test | 165°C | IEC 60695-10-2 | Pass | |
| 125°C | IEC 60695-10-2 | PassPass | ||
| Vicat softening temperature | ISO 306/B120 | 205 | °C | |
| 1.8MPa, unannealed, 64.0mm span of | ISO 75-2/Af | 185 | °C | |
| 0.45MPa, unannealed, 64.0mm span | ISO 75-2/Bf | 208 | °C | |
| 0.45MPa, unannealed, 3.20mm | ASTM D648 | 209 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 23°C,24hr | ISO 62 | 0.36 | % |
| Shrinkage rate | MD:24hr | ISO 294-4 | 0.45 | % |
| TD:24hr | ISO 294-4 | 0.65 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| High arc combustion index | HAI | UL 746 | PLC 0 | |
| Compared to the anti leakage trace index | CTI | UL 746 | PLC 0 | |
| Dielectric strength | 1.60mm,inOil | ASTM D149 | 16 | KV/mm |
| Surface resistivity | ASTM D257 | 1E+16 | ohms | |
| Hot wire ignition | HWI | UL 746 | PLC 0 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.