Share
Add to Compare

PC 050/45S ALMAAK GERMANY

Typical Applications:
Toys medical nursing supplies pipe fittings
Product Description
Certificates(0)
Datasheet

Product Description

Typical Applications:Toys | medical | nursing supplies | pipe fittings

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Charpy Notched Impact Strength23°CISO 179/1eA45kJ/m²
Impact strength of simply supported beam without notch23°CISO 179/1eU无断裂
flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant rating1.6mmUL 94HB
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Tensile strainBreakISO 527-2/505.0%
tensile strengthYieldISO 527-2/5054.0MPa
Tensile modulusISO 527-2/12000MPa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Vicat softening temperatureISO 306/B50110°C
Hot deformation temperature1.8MPa,UnannealedISO 75-2/A105°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Shrinkage rateTDISO 294-40.50to0.70%
Melt Volume Flow Rate (MVR)260°C/5.0kgISO 113324.0cm³/10min
density23°CISO 11831.10g/cm³
Water absorption rateEquilibrium,23°C,50%RHISO 620.20%
Water absorption rate23°C,24hrISO 620.70%
Shrinkage rateMDISO 294-40.50to0.70%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Compared to the anti leakage trace indexIEC 60112PLC 2
Dielectric strengthIEC 60243-124kV/mm
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.