PC 2805 021139 COVESTRO GERMANY
185
Form:Granules | Grade:Light diffusion level
Properties:
Medium viscosityMedium viscosityFor general injection mol
Typical Applications:
Automotive ApplicationsElectrical applicationsIndustrial applicationsUsed for industrial accessoriesAutomotive electronic componentsElectronic and electrical accessories; ul certific
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive Applications | Electrical applications | Industrial applications | Used for industrial accessories | Automotive electronic components | Electronic and electrical accessories; ul certific |
| Properties: | Medium viscosity | Medium viscosity | For general injection mol |
Certificates
No Data...
Technical Data Sheet
| other | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| density | -- | ISO 1183 | 1200 | kg/m2 |
| Water absorption rate | 23℃:50%rh,静态均衡值 | ISO 62 | 0.12 | % |
| 在23℃水中,Saturation值 | ISO 62 | 0.30 | % | |
| Specific properties of raw materials | Test Condition | Test Method | Test Result | Test Unit |
| Transmittance rate | 1毫米 | ISO 13468-2 | 89 | % |
| Refractive index | 过程A | ISO 489 | 1.586 | -- |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile creep modulus | 23℃/50%r.h 1hr | ISO 899-1 | 2200 | MPa |
| Fracture strain | 23℃/50%r.h 5毫米/分钟 | ISO 527-1-2 | -- | % |
| Tensile creep modulus | 23℃/50%r.h 1000hr | ISO 899-1 | 1900 | MPa |
| Bending modulus | 23℃/50%r.h 2毫米/分钟 | ISO 179 | 2400 | MPa |
| Charpy Notched Impact Strength | 23℃/50%r.h | ISO 179/1eU | N | kJ/m² |
| 23℃/50%r.h ;3毫米 | kJ/m² | 参照ISO 179/1eA | 75P(C) | |
| Impact strength of cantilever beam gap | 23℃/50%r.h ;3.2毫米 | kJ/m² | 参照ISO 180/1eA | 85P(C) |
| Maximum destructive power | 23℃/50%r.h | ISO 6603-2 | 5400 | N |
| tensile strength | 23℃/50%r.h,Break | ISO 6603-2 | 60 | J |
| Fracture stress | 23℃/50%r.h 5毫米/分钟 | ISO 527-1-2 | -- | MPa |
| Elongation at Break | 23℃/50%r.h 50毫米/分钟 | ISO 527-1-2 | >50 | % |
| Tensile strain | 23℃/50%r.h 50毫米/分钟,Yield | ISO 527-1-2 | 6.1 | % |
| Tensile stress | 23℃/50%r.h 50毫米/分钟,Yield | ISO 527-1-2 | 66 | MPa |
| Tensile modulus | 23℃/50%r.h 1毫米/分钟 | ISO 527-1-2 | 2400 | MPa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Glass transition temperature | 10℃/毫米 | ISO 11357-1-2 | 145 | ℃ |
| Vicat softening temperature | 50N;50℃/hr | ISO 306 | 145 | ℃ |
| Linear coefficient of thermal expansion | 23-55℃,垂直 | ISO 11359-1-2 | 0.65 | 10-4/K |
| 23-55℃,Flow | ISO 11359-1-2 | 0.65 | 10-4/K | |
| UL flame retardant rating | 1.5毫米 | UL 94 | V-2 | 级 |
| 厚度 | UL 94 | HB(2.5) | 级 | |
| Extreme Oxygen Index | A溶液 | ISO 4589-2 | 27 | % |
| Glow wire combustion index (GWFI) | 1.5毫米 | IEC 60695-2-12 | 850 | ℃ |
| 1.0毫米 | IEC 60695-2-12 | 930 | ℃ | |
| Glow wire ignition temperature (GWIT) | 1.5毫米 | IEC 60695-2-13 | 875 | ℃ |
| 3.0毫米 | IEC 60695-2-13 | 875 | ℃ | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | 60*60*2;500bar,垂直 | ISO 294-4 | 0.7 | % |
| 60*60*2;500bar,Flow | ISO 294-4 | 0.65 | % | |
| melt mass-flow rate | 300℃;1.2kg | ISO 1133 | 9.5 | cm3/(10分钟) |
| 250℃;2.16kg | ISO 1133 | -- | cm3/(10分钟) | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the Leakage Traceability Index (CTI) | 23℃/50%r.h 方法A | IEC 60112 | 250 | 等级 |
| Volume resistivity | 23℃/50%r.h | IEC 60093 | 1E+14 | Ohm.m |
| Dielectric constant | 23℃/50%r.h 100Hz | IEC 60250 | 3.1 | -- |
| Dissipation factor | 23℃/50%r.h 100Hz | IEC 60250 | 5 | 10-4 |
| Dielectric constant | 23℃/50%r.h 1MHz | IEC 60250 | 3.0 | -- |
| Dissipation factor | 23℃/50%r.h 1MHz | IEC 60250 | 90 | 10-4 |
| Dielectric strength | 23℃/50%r.h 1毫米 | IEC 60243-1 | 34 | kv/毫米 |
| Surface resistivity | 23℃/50%r.h | IEC 60093 | 1E+16 | Ohm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.