PA66 Vydyne® ECO315
33
- Properties:low densityLubricityElongated elongation rateResistance to stress cracGood demolding performancDuctilityGood flexibilityHalogen-freeFlame retardant
- Usages:Electrical fieldElectronic fieldMovable hingeSpoolElectrical componentsFastenersprinted circuit boardElectrical enclosureSwitch panelLighting applicationsElectrical appliancesLaptop caseIndustrial applicationsAutomotive sector
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | ISO294-4 | 1.4 % | |
ISO294-4 | 1.2 % | ||
Water absorption rate | ISO62 | 0.80 % | |
ISO62 | 2.3 % |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL94 | V-0 | |
UL94 | V-0 | ||
UL94 | V-0 | ||
UL94 | V-0 | ||
Burning wire flammability index | IEC60695-2-12 | 960 °C | |
IEC60695-2-12 | 960 °C | ||
IEC60695-2-12 | 960 °C | ||
IEC60695-2-12 | 960 °C | ||
Hot filament ignition temperature | IEC60695-2-13 | 875 °C | |
IEC60695-2-13 | 875 °C | ||
IEC60695-2-13 | 775 °C | ||
IEC60695-2-13 | 725 °C | ||
Limiting Oxygen Index | ISO4589-2 | 29 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | ISO179/1eU | NoBreak | |
ISO179/1eU | NoBreak |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ISO527-2 | 5000 Mpa | |
Tensile stress | ISO527-2 | 75.0 Mpa | |
Tensile strain | ISO527-2 | 5.5 % | |
ISO527-2 | 25 % | ||
Flexural modulus | ISO178 | 3200 Mpa | |
bending strength | ISO178 | 92.0 Mpa | |
Poisson's ratio | ISO527-2 | 0.40 |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Hot wire ignition (HWI) | UL746 | PLC 4 | |
UL746 | PLC 4 | ||
UL746 | PLC 3 | ||
VolumeResistivity | IEC60093 | 1E+11 ohms·cm | |
dielectric strength | IEC60243 | 13 KV/mm | |
arc resistance | ASTMD495 | PLC 5 | |
CTI | IEC60112 | 600 V | |
High arc combustion index (HAI) | UL746 | PLC 0 | |
UL746 | PLC 0 | ||
UL746 | PLC 0 | ||
UL746 | PLC 0 | ||
High Voltage Arc Traceability Rate (HVTR) | UL746 | PLC 1 | |
Hot wire ignition (HWI) | UL746 | PLC 4 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ISO75-2/B | 225 °C | |
ISO75-2/A | 65.0 °C | ||
melting temperature | ISO11357-3 | 244 °C | |
ISO11359-2 | 1.1E-04 cm/cm/°C | ||
ISO11359-2 | 1.1E-04 cm/cm/°C | ||
RTI Elec | UL746 | 130 °C | |
UL746 | 130 °C | ||
UL746 | 130 °C | ||
UL746 | 130 °C | ||
RTI Imp | UL746 | 65.0 °C | |
UL746 | 65.0 °C | ||
UL746 | 85.0 °C | ||
UL746 | 85.0 °C | ||
RTI Str | UL746 | 100 °C | |
UL746 | 100 °C | ||
UL746 | 100 °C | ||
UL746 | 110 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.