Epoxy 301-2 Epoxy Technology Inc.

Typical Applications:
Immersion applications laminated boards LCD Application medical nursing supplies adhesives optical applications light-emitting diodes adhesives seals electrical electronic application fields
Product Description
Certificates(0)
Datasheet

Product Description

Typical Applications:Immersion applications | laminated boards | LCD | Application | medical | nursing supplies | adhesives | optical applications | light-emitting diodes | adhesives | seals | electrical | electronic application fields

Certificates

No Data...

Technical Data Sheet

Cured PropertiesTest ConditionTest MethodTest ResultTest Unit
Dissipation factor1kHz0.012
Volume resistivity>2.0E+12ohms·cm
Relative permittivity1kHz3.80
LapShearStrength23°C>13.8MPa
Shore hardnessShoreD80
Uncured PropertiesTest ConditionTest MethodTest ResultTest Unit
Color--7Clear/Transparent
densityPartA1.02g/cm³
density粘度8(23°C)0.23to0.43Pa·s
density固化时间(80°C)3.0hr
densityPot Life480min
densityPartB0.888g/cm³
Color--6Clear/Transparent
optical performanceTest ConditionTest MethodTest ResultTest Unit
transmissivity1200to1600nm>98.0%
transmissivity400to1200nm>99.0%
transmissivity320nm>94.0%
Refractive index1.532
thermosettingTest ConditionTest MethodTest ResultTest Unit
Thermosetting componentsShelf Life(23°C)52wk
Thermosetting componentsPartB按重量计算的混合比:35
Thermosetting components按重量计算的混合比100
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Glass transition temperature>80.0°C
Linear coefficient of thermal expansionMD:--36.1E-05cm/cm/°C
Linear coefficient of thermal expansionMD:--41.8E-04cm/cm/°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Ionic typeNa+104ppm
Ionic typeNH4+NotDetectable
Ionic typeCl-61ppm
Ionic typeK+NotDetectable
Supplementary InformationTest ConditionTest MethodTest ResultTest Unit
weight loss on heating300°C2.2%
operate temperatureContinuous-55-200°C
Shear Strength23°C35.2MPa
DegradationTemperatureTGA360°C
weight loss on heating250°C0.46%
weight loss on heating200°C0.010%
operate temperatureStorageModulus2.06GPa
operate temperatureIntermittent-55-300°C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.