PC NCF15 FR

0
  • Usages:
    Electromagnetic shielding
    (EMI)
    flame retardant performance

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
Shrinkage rateASTM D-9550.2 %
Basic performanceTest ConditionTest MethodTest Result
densityASTM D-7921.33 g/cm3
Water absorption rateASTM D-5700.1 %
Mechanical propertiesTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapASTM D-25664.9 J/m
Suspended wall beam without notch impact strengthASTM D-256347 J/m
tensile strength ASTM D-638126 MPa
elongation at breakASTM D-6382.8 %
Flexural modulusASTM D-7907580 MPa
bending strengthASTM D-790152 MPa
Electrical performanceTest ConditionTest MethodTest Result
Surface ResistivityASTM D-2571E+04 ohms
Volume resistivityASTM D-2571E+04 ohm·cm
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureASTM D-648144
UL flame retardant ratingUL 94V-0
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.