PPS 1140L7 SD3002 CELANESE USA

32

Form:Granules | Grade:Injection grade

Properties:
Flame retardantGlass fiber reinforcedHigh temperature resistan
Typical Applications:
fibreBottle cap
Product Description
Certificates(0)
Datasheet

Product Description

Typical Applications:fibre | Bottle cap
Properties:Flame retardant | Glass fiber reinforced | High temperature resistan

Certificates

No Data...

Technical Data Sheet

flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant rating0.38 mmUL 94V-0
UL flame retardant rating1.5 mmUL 94V-0
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Tensile modulusISO 527-2/1A14500Mpa
tensile strengthBreakISO 527-2/1A/5170Mpa
Tensile strainBreakISO 527-2/1A/51.6%
Bending modulus23°CISO 17814500Mpa
bending strengthISO 178260Mpa
Compressive modulusISO 60414000Mpa
injectionTest ConditionTest MethodTest ResultTest Unit
drying temperature130 to 140°C
drying time3.0 to 4.0hr
Suggested maximum moisture content0.020%
Hopper temperature20 to 30°C
Temperature at the rear of the barrel290 to 300°C
Temperature in the middle of the barrel310 to 320°C
Temperature at the front of the material cylinder330 to 340°C
Spray nozzle temperature310 to 330°C
Processing (melt) temperature330 to 340°C
Mold temperature140 to 160°C
Injection speed快速
Back pressure< 3.00Mpa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature1.8 MPa, UnannealedISO 75-2/A270°C
Hot deformation temperature8.0 MPa, UnannealedISO 75-2/C200°C
Glass transition temperatureISO 11357-290.0°C
Melting temperatureISO 11357-3280°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Shrinkage rate横向FlowISO 294-40.50 - 0.70%
Shrinkage rateFlowISO 294-40.10 - 0.30%
Water absorption rateSaturation, 23°CISO 620.020%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Surface resistivityIEC 60093> 1.0E+15ohms
Volume resistivityIEC 60093> 1.0E+15ohms·cm
Dielectric strengthIEC 60243-126KV/mm
Compared to the anti leakage trace indexIEC 60112PLC 4
hardnessTest ConditionTest MethodTest ResultTest Unit
Rockwell hardnessM -SaleISO 2039-2100
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.