Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
MediumDensity | | | 0.900 g/cm³ |
SpecificHeatCapacity of Melt | | | 2750 J/kg/°C |
ThermalConductivityofMelt | | | 0.18 W/m/K |
Shrinkage rate | | | 1.1 % |
Shrinkage rate | | | 1.1 % |
Shrinkage rate | | ISO 294-4 | 1.4 % |
Shrinkage rate | | ISO 294-4 | 1.3 % |
Water absorption rate | | ISO 62 | 3.0 % |
Water absorption rate | | ISO 62 | 1.3 % |
viscosity number | | ISO 307 | 95.0 cm³/g |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | | ISO 2039-2 | 114 |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | V-2 |
UL flame retardant rating | | UL 94 | V-2 |
UL flame retardant rating | | IEC 60695-11-10,-20 | V-2 |
UL flame retardant rating | | IEC 60695-11-10,-20 | V-2 |
Limiting Oxygen Index | | ISO 4589-2 | 27 % |
FMVSS flammability | | FMVSS302 | DNI |
Supplementary Information | Test Condition | Test Method | Test Result |
---|
Emissions of Organic Compounds | | VDA277 | 3.10 µgC/g |
Odor | | VDA270 | 4.50 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Nominal tensile fracture strain | | ISO 527-2 | 17 % |
Flexural modulus | | ISO 178 | 2100 Mpa |
Tensile modulus | | ISO 527-2 | 2400 Mpa |
tensile strength | | ISO 527-2 | 62.0 Mpa |
Tensile strain | | ISO 527-2 | 4.5 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of simply supported beam without notch | | ISO 179/1eU | NoBreak |
Impact strength of simply supported beam without notch | | ISO 179/1eU | NoBreak |
film | Test Condition | Test Method | Test Result |
---|
Tensile strain | | ISO 527-3 | 4.5 % |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | IEC 60093 | -- ohms |
Volume resistivity | | IEC 60093 | 1E+15 ohms·cm |
dielectric strength | | IEC 60243-1 | 30 KV/mm |
| | IEC 60250 | 3.60 |
| | IEC 60250 | 3.20 |
Dissipation Factor | | IEC 60250 | 0.014 |
Dissipation Factor | | IEC 60250 | 0.016 |
Compared to the Leakage Tracking Index (CTI) | | IEC 60112 | PLC 0 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ISO 11359-2 | 1.8E-04 cm/cm/°C |
Hot deformation temperature (HDT) | | ISO 75-2/B | 135 °C |
Hot deformation temperature (HDT) | | ISO 75-2/A | 62.0 °C |
Glass Transition Temperature | | ISO 11357-2 | 65.0 °C |
vicat | | ISO 306/B50 | 181 °C |
melting temperature | | ISO 11357-3 | 218 °C |
| | ISO 11359-2 | 1.1E-04 cm/cm/°C |
| | ISO 11359-2 | 9E-05 cm/cm/°C |
| | ISO 11359-2 | 1.6E-04 cm/cm/°C |
| | ISO 11359-2 | 1.2E-04 cm/cm/°C |
| | ISO 11359-2 | 9E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.