PC 8600 WH STYRON TAIWAN
31
Form:Granules | Grade:Injection grade
Properties:
Flame retardant
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Flame retardant |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Dart impact | 23°C,3.20mm,Injection,总能量 | ASTM D3763 | 58.8 | J |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.50mm | UL 94 | V-0 | |
| 3.00mm | UL 94 | V-0 | ||
| Burning wire flammability index | 1.00mm | IEC 60695-2-12 | 960 | °C |
| Extreme Oxygen Index | ASTM D2863 | 35 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| elongation | Break,3.20mm,Injection | ASTM D638 | 110 | % |
| Bending modulus | 3.20mm,Injection | ASTM D790 | 2400 | Mpa |
| bending strength | 3.20mm,Injection | ASTM D790 | 93.8 | Mpa |
| Tensile modulus | 3.20mm,Injection | ASTM D638 | 2210 | Mpa |
| tensile strength | Yield,3.20mm,Injection | ASTM D638 | 60.0 | Mpa |
| Break,3.20mm,Injection | ASTM D638 | 57.9 | Mpa | |
| elongation | Yield,3.20mm,Injection | ASTM D638 | 6.2 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa,Unannealed | ASTM D648 | 139 | °C |
| 1.8MPa,Unannealed | ASTM D648 | 127 | °C | |
| Vicat softening temperature | ASTM D15252 | 149 | °C | |
| Linear coefficient of thermal expansion | MD:-40to82°C | ASTM D696 | 6.5E-05 | cm/cm/°C |
| RTI Elec | 3.20mm | UL 746 | 125 | °C |
| RTI Imp | 3.20mm | UL 746 | 125 | °C |
| RTI | 3.20mm | UL 746 | 125 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | 300°C/1.2kg | ASTM D1238 | 7.0 | g/10min |
| Shrinkage rate | MD | ASTM D955 | 0.50-0.70 | % |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Scale,3.20mm,Injection | ASTM D785 | 123 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.