PPS Lion Idemitsu Composites PPS G142Z1 Lion Idemitsu Composites Co., Ltd.
Properties:
Filler glass mineral 70% filler by weight
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | glass mineral | 70% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | ISO 179 | 14 | kJ/m² | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | ISO 178 | 198 | MPa | |
| Bending modulus | ISO 178 | 25600 | MPa | |
| Tensile strain | Break | ISO 527-2 | 0.60 | % |
| tensile strength | ISO 527-2 | 114 | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | TD | ISO 11359-2 | 2E-05 | cm/cm/°C |
| MD | ISO 11359-2 | 1.1E-05 | cm/cm/°C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 286 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 23°C,24hr | ISO 62 | >0.020 | % |
| Shrinkage rate | MD | ISO 294-4 | 0.30 | % |
| TD | ISO 294-4 | 0.30 | % | |
| density | ISO 1183 | 2.00 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dissipation factor | IEC 60250 | 1.5E-03 | ||
| Dielectric constant | IEC 60250 | 4.70 | ||
| Dielectric strength | 1.00mm | IEC 60243-1 | 25 | kV/mm |
| Volume resistivity | ASTM D257 | 1E+16 | ohms·cm | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Sale | ISO 2039-2 | 117 | |
| M-Sale | ISO 2039-2 | 94 | ||
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| Flowability | 1.00mm,Flowability | Internal Method | 110 | mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.