Technical Data Sheet
Test Condition | Test Method | Test Result | |
---|---|---|---|
dielectric constant | IEC60250 | 2.30 | |
Power factor | IEC250 | 4E-04 | |
density | ASTMD1505 | 0.930 g/cm³ | |
Volume resistivity | IEC60502 | 1.4E+15 ohms·cm | |
dielectric strength | IEC60243-1 | 25 kV/mm | |
melt mass-flow rate | ASTMD1238 | 1.1 g/10min | |
tensile strength | IEC60811 | 19.0 MPa | |
Tensile strain | Break | IEC60811 | 550 % |
Change rate of tensile strength in air | IEC60811 | 10 % | |
Changes in tensile stress during fracture in air | IEC60811 | -10 % | |
thermosetting | IEC60811 | 100 % | |
IEC60811 | 5.0 % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.