XLPE Polylink Polymer PP 408-401-P-10040-B Polylink Polymers (India) Ltd.
0
- Properties:Electrical performance
Technical Data Sheet
Test Condition | Test Method | Test Result | |
---|---|---|---|
dielectric constant | IEC 60250 | 2.30 | |
Loss factor | IEC 250 | 4E-04 | |
density | ASTM D1505 | 0.930 g/cm³ | |
Volume resistivity | IEC 60502 | 1.4E+15 ohms·cm | |
dielectric strength | IEC 60243-1 | 25 kV/mm | |
melt mass-flow rate | ASTM D1238 | 1.1 g/10min | |
tensile strength | IEC 60811 | 19.0 MPa | |
Tensile strain | Break | IEC 60811 | 550 % |
Change rate of tensile strength in air | IEC 60811 | 10 % | |
Tensile stress change rate | IEC 60811 | -10 % | |
thermosetting | IEC 60811 | 100 % | |
IEC 60811 | 5.0 % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.