PA66 WELLAMID Nylon 6600/42 HWCP CP-Polymer-Technik GmbH & Co. KG
Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | 23℃ | kJ/m² | 3.065to3.343 | |
| Impact strength of simply supported beam without notch | 23℃ | kJ/m² | 11.143to19.964 | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | Break,23℃ | 144.83to292.41 | Mpa | |
| Tensile modulus | 23℃ | 8206.9to28000.0 | Mpa | |
| Tensile strain | Break,23℃ | % | 1.9to3.1 | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Continuous use temperature | °C | 110to220 | ||
| transverse | mm/mm/°C | 68.6E-5-127.0E-5 | ||
| flow | mm/mm/°C | 142.2E-5-203.2E-5 | ||
| Melting temperature | °C | 260 | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| saturated | % | 3.5to5.0 | ||
| density | 23℃ | g/cm³ | 1.28to1.85 | |
| balance | % | 1.2to1.5 | ||
| Shrinkage rate | 23℃ | % | 0.10to0.31 | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric strength | 23℃ | V/mil | 840 | |
| Volume resistivity | 23℃ | ohms·cm | 1.0E+12到1.0E+14 | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Ball Pressure Test | 222.76to370.34 | Mpa |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.