PBT XFR4840 CELANESE USA
112
Form:Granules | Grade:Halogen-free flame retardant grade
Properties:
Easy to processHalogen-freeFlame retardantGood processabilityHalogen-freeAntimony freeFlame retardancy
Typical Applications:
Automotive sectorElectronic and electrical accessories
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive sector | Electronic and electrical accessories |
| Properties: | Easy to process | Halogen-free | Flame retardant | Good processability | Halogen-free | Antimony free | Flame retardancy |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 32 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.8mm | UL 94 | V-0 | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2/1A/1 | 3300 | Mpa | |
| tensile strength | Break | ISO 527-2/1A/50 | 45.0 | Mpa |
| Tensile strain | Break | ISO 527-2/1A/50 | 14 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8 MPa, Unannealed | ISO 75-2/A | 70 | °C |
| Melting temperature | ISO 11357-3 | 225 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 70.0 | °C |
| Melting temperature | ISO 11357-3 | 225 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2/1A/1 | 3300 | Mpa | |
| tensile strength | Break | ISO 527-2/1A/5 | 45 | Mpa |
| Tensile strain | Break | ISO 527-2/1A/5 | 14 | % |
| Impact strength of simply supported beam without notch | 23℃ | ISO 179/1eU | 32 | kJ/m² |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | IEC 60112 | PLC 0 | ||
| flame retardant performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL 94 | V-0 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.