PC 3412R-131 SABIC INNOVATIVE JAPAN
78
Form:Granules | Grade:Injection grade
Properties:
Flame retardantenhanceGlass fiber reinforced
Typical Applications:
Automotive sector
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Automotive sector |
| Properties: | Flame retardant | enhance | Glass fiber reinforced |
Certificates

Technical Data Sheet
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Water absorption rate | ASTM D-570 | 0.16 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | ASTM D-790 | 131 | Mpa | |
| tensile strength | ASTM D-638 | 110 | Mpa | |
| Rockwell hardness | ASTM D-785 | 122 | ||
| elongation | Break | ASTM D-638 | 5 | % |
| Impact strength of cantilever beam gap | 23°C | ASTM D-256 | 107 | J/m |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa | ASTM D-648 | 148 | °C |
| 1.8MPa | ASTM D-648 | 146 | °C | |
| Linear coefficient of thermal expansion | ASTM E-831 | 2.7×10 | 1/°C | |
| Vicat softening temperature | ASTM D-1525 | 165 | °C | |
| Long term use temperature | UL 746B | 130 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | 3.2mm | ASTM D-955 | 1-3 | |
| Bending modulus | ASTM D-790 | 5512 | Mpa | |
| enhance | 20 | % | ||
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dissipation factor | 1MHz | ASTM D-150 | 0.0073 | |
| Dielectric constant | 1MHz | ASTM D-150 | 3.13 | |
| Dissipation factor | 60Hz | ASTM D-150 | 0.0009 | |
| Dielectric constant | 60Hz | ASTM D-150 | 3.17 | |
| Volume resistivity | ASTM D-257 | 1.0×10 | Ω.cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.