PP LUBLENE GC30 NATURAL LUBEN PLAST srl
Properties:
Filler glass fiber reinforced material 30% filler by weight
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | glass fiber reinforced material | 30% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 8.0to9.0 | kJ/m² |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 40to50 | kJ/m² |
| Suspended wall beam without notch impact strength | 23°C | ISO 180 | 40to50 | kJ/m² |
| Impact strength of cantilever beam gap | 23°C | ISO 180/A | 8.0to9.0 | kJ/m² |
| 23°C4 | ASTM D256 | 8.0to9.0 | kJ/m² | |
| 23°C3 | ASTM D256 | 40to50 | kJ/m² | |
| 23°C,3.20mm | ASTM D256A | 80to90 | J/m | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | ISO 178 | 70.0to80.0 | MPa | |
| Bending modulus | ISO 178 | 4000to5000 | MPa | |
| Tensile strain | Break | ISO 527-2/1A/5 | 2.5to3.0 | % |
| Yield | ISO 527-2/1A/5 | 2.5to3.0 | % | |
| tensile strength | Break | ISO 527-2/1A/5 | 65.0to75.0 | MPa |
| Yield | ISO 527-2/1A/5 | 65.0to75.0 | MPa | |
| Tensile modulus | ISO 527-2/1A/1 | 4500to5500 | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa,Unannealed,3.20mm | ASTM D648 | 145to155 | °C |
| 0.45MPa,Unannealed | ISO 75-2/B | 145to155 | °C | |
| 1.8MPa,Unannealed,3.20mm | ASTM D648 | 130to140 | °C | |
| Vicat softening temperature | -- | ISO 306/B120 | 125to135 | °C |
| -- | ISO 306/A120 | 155to165 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183/A | 1.10to1.14 | g/cm³ |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.