Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ISO 1183 | 1.56 g/cm³ |
Water absorption rate | | ISO 62 | 0.020 % |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | R-Scale | ISO 2039-2 | 120 |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | V-0 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | | ISO 527-2 | 145 MPa |
Tensile strain | Break | ISO 527-2 | 6.0 % |
Flexural modulus | | ISO 178 | 8000 MPa |
bending strength | | ISO 178 | 210 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Suspended wall beam without notch impact strength | | ISO 180 | 12 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric strength | | ASTM D149 | 16 kV/mm |
dielectric constant | | ASTM D150 | 3.60 |
Dissipation Factor | | ASTM D150 | 2E-03 |
Volume resistivity | | ISO 167 | 5E+16 ohms·cm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ISO 75-2 | 265 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.