POM Delrin® 900P

805
  • Properties:
    wear resistant
    High rigidity
    high strength
    enhance
    High impact resistance
    High mobility
  • Usages:
    Fiber grade
    Thin walled products
  • Certificates:
    UL
    UL

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityISO 11831.42 g/cm³
melt mass-flow rateISO 113325 g/10min
Melt volume flow rateISO 113321.0 cm3/10min
Shrinkage rateISO 294-41.9 %
Shrinkage rateISO 294-41.9 %
Water absorption rateISO 621.4 %
Water absorption rateISO 620.40 %
hardnessTest ConditionTest MethodTest Result
Rockwell hardnessISO 2039-292
Rockwell hardnessISO 2039-2120
flammabilityTest ConditionTest MethodTest Result
burning rateISO 379520 mm/min
UL flame retardant ratingUL 94HB
UL flame retardant ratingUL 94HB
UL flame retardant ratingIEC 60695-11-10,-20HB
UL flame retardant ratingIEC 60695-11-10,-20HB
Limiting Oxygen IndexISO 4589-223 %
FMVSS flammabilityFMVSS302B
atomizationISO 645295 %
atomizationISO 64522E-04 g
Supplementary InformationTest ConditionTest MethodTest Result
Emissions of Organic CompoundsVDA2774.30 µgC/g
EmissionVDA275<8.00 mg/kg
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapISO 180/1A7.0 kJ/m²
Charpy Notched Impact StrengthISO 179/1eA7.0 kJ/m²
Charpy Notched Impact StrengthISO 179/1eA8.0 kJ/m²
Impact strength of simply supported beam without notchISO 179/1eU200 kJ/m²
Impact strength of simply supported beam without notchISO 179/1eU200 kJ/m²
Impact strength of cantilever beam gapISO 180/1A8.0 kJ/m²
Mechanical propertiesTest ConditionTest MethodTest Result
Nominal tensile fracture strainISO 527-223 %
Tensile creep modulusISO 899-12800 Mpa
Tensile creep modulusISO 899-11500 Mpa
Flexural modulusISO 1783000 Mpa
coefficient of frictionASTM D18940.25
Tensile modulusISO 527-23300 Mpa
tensile strength ISO 527-271.0 Mpa
Tensile strainISO 527-212 %
Electrical performanceTest ConditionTest MethodTest Result
Surface ResistivityIEC 60093>1.0E+15 ohms
Volume resistivityIEC 600931E+14 ohms·cm
relative permittivityIEC 602503.80
relative permittivityIEC 602503.80
Compared to the Leakage Tracking Index (CTI)IEC 60112PLC 0
Hot wire ignition (HWI)UL 746PLC 4 sec
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureISO 75-2/B162 °C
Heat distortion temperatureISO 75-2/A94.0 °C
vicatISO 306/B50160 °C
melting temperatureISO 11357-3178 °C
Linear coefficient of thermal expansionASTME8311E-04 cm/cm/°C
Linear coefficient of thermal expansionISO 11359-21.2E-04 cm/cm/°C
Linear coefficient of thermal expansionISO 11359-21.2E-04 cm/cm/°C
AnnealingTemperature160 °C
AnnealingTime-Optional30.0 min/mm
Effective thermal diffusivity coefficient8E-08 m²/s
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.

Contact Us

Get App

Top