PBT PB70 GR30 IL MELOS GERMANY
8
Form:Granules | Grade:Injection grade
Properties:
Low friction coefficientImpact resistanceThermal insulationAging resistanceHigh glossDimensional stabilityFiller: Glass fiber reinf30%Filler by weight
Typical Applications:
Electronic fieldElectrical field
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electronic field | Electrical field |
| Properties: | Low friction coefficient | Impact resistance | Thermal insulation | Aging resistance | High gloss | Dimensional stability | Filler: Glass fiber reinf | 30% | Filler by weight |
Certificates
No Data...
Technical Data Sheet
| other | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| purpose | 车辆配件 | |||
| characteristic | 加纤30% 增强级 冲击改性 | |||
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Suspended wall beam without notch impact strength | 23°C | ISO 180/1U | 65 | kJ/m² |
| -30°C | ISO 180/1U | 60 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Hot filament ignition temperature | 2.0mm | IEC 60695-2-13 | 725 | °C |
| Burning wire flammability index | 2.0mm | IEC 60695-2-12 | 960 | °C |
| UL flame retardant rating | 1.6mm | UL 94 | V-0 | |
| 0.75mm | UL 94 | V-0 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile strain | Break,23°C | ISO 527-2 | 2.0 | % |
| tensile strength | Break,23°C | ISO 527-2 | 130 | Mpa |
| Tensile modulus | 23°C | ISO 527-2 | 11000 | Mpa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 220 | °C |
| Melting temperature | ISO 11357-3 | 225 | °C | |
| Vicat softening temperature | ISO 306/B | 210 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 205 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| water content | ISO 15512 | <0.080 | % | |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.20 | % |
| Shrinkage rate | MD | Internal Method | 0.30 | % |
| TD | Internal Method | 1.0 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | SolutionA | IEC 60112 | PLC 3 | |
| Volume resistivity | IEC 60093 | 1E+16 | ohms·cm | |
| Surface resistivity | IEC 60093 | 1E+14 | ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.