PES Ultraform®E  E2010G6

450
  • Properties:
    High temperature resistan
    Flame retardant
  • Usages:
    medical care
    Home appliance components
  • Certificates:
    UL

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityISO11831.37 g/cm³
Melt volume flow rateISO113370.0 cm3/10min
Shrinkage rateISO294-40.86 %
Shrinkage rateISO294-40.82 %
Water absorption rateISO622.2 %
Water absorption rateISO620.80 %
hardnessTest ConditionTest MethodTest Result
ISO2039-1154 Mpa
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL94V-0
UL flame retardant ratingUL94V-0
Impact resistanceTest ConditionTest MethodTest Result
Charpy Notched Impact StrengthISO1797.0 kJ/m²
Impact strength of simply supported beam without notchISO179NoBreak
Impact strength of simply supported beam without notchISO179NoBreak
Impact strength of cantilever beam gapISO1807.5 kJ/m²
Impact strength of cantilever beam gapISO1807.0 kJ/m²
Charpy Notched Impact StrengthISO1797.5 kJ/m²
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusISO527-22650 Mpa
Tensile stressISO527-285.0 Mpa
Tensile strainISO527-26.9 %
Electrical performanceTest ConditionTest MethodTest Result
Surface ResistivityIEC60093>1.0E+15 ohms
Volume resistivityIEC60093>1.0E+13 ohms·cm
dielectric strengthIEC60243-137 KV/mm
dielectric constantIEC602503.90
dielectric constantIEC602503.80
Dissipation FactorIEC602501.7E-03
Dissipation FactorIEC602500.014
CTIIEC60112125 V
Thermal performanceTest ConditionTest MethodTest Result
RTI ImpUL746180 °C
RTI ImpUL746180 °C
RTI StrUL746190 °C
RTI StrUL746190 °C
ISO75-2/A205 °C
5.2E-05 cm/cm/°C
RTI ElecUL746180 °C
RTI ElecUL746180 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.