Phenolic Resinoid 1360 Resinoid Engineering Corporation
0
- Properties:Fillersglass fiber reinforced materials
- Usages:Electrical components
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ASTM D792 | 1.74 g/cm³ | |
Water absorption rate | ASTM D570 | 0.10 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
tensile strength | Yield | ASTM D638 | 48.3 MPa |
Flexural modulus | ASTM D790 | 17900 MPa | |
bending strength | Yield | ASTM D790 | 138 MPa |
compressive strength | ASTM D695 | 240 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of cantilever beam gap | ASTM D256 | 190 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
dielectric strength | ASTM D149 | 13 kV/mm |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ASTM D648 | 300 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.