Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | ISO 62 | 8.5 % |
Water absorption rate | | ISO 62 | 2.9 % |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | V-0 |
UL flame retardant rating | | UL 94 | V-0 |
UL flame retardant rating | | UL 94 | V-0 |
UL flame retardant rating | | UL 94 | V-0 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO 527-2 | 3770 Mpa |
tensile strength | | ISO 527-2 | 84.0 Mpa |
Tensile strain | | ISO 527-2 | 3.7 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of simply supported beam without notch | | ISO 179 | 69 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Compared to the Leakage Tracking Index (CTI) | | IEC 60112 | PLC 0 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
RTI Imp | | UL 746 | 105 °C |
RTI Str | | UL 746 | 65.0 °C |
RTI Str | | UL 746 | 115 °C |
RTI Str | | UL 746 | 120 °C |
RTI Str | | UL 746 | 120 °C |
Heat distortion temperature | | ISO 75-2/A | 68.0 °C |
melting temperature | | ISO 3146 | 243 °C |
RTI Elec | | UL 746 | 110 °C |
RTI Elec | | UL 746 | 120 °C |
RTI Elec | | UL 746 | 120 °C |
RTI Elec | | UL 746 | 120 °C |
RTI Imp | | UL 746 | 65.0 °C |
RTI Imp | | UL 746 | 105 °C |
RTI Imp | | UL 746 | 105 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.