Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ISO1183 | 1.14 g/cm³ |
Shrinkage rate | | | 0.70to1.2 % |
Water absorption rate | | | 1.3 % |
flammability | Test Condition | Test Method | Test Result |
---|
Burning wire flammability index | | IEC60695-2-12 | 650 °C |
FlameRating | | UL94 | HB |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of simply supported beam without notch | | ISO179 | 44 kJ/m² |
Charpy Notched Impact Strength | | ISO179 | 11 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO527-2 | 4400 MPa |
Tensile stress | Break | ISO527-2 | 120 MPa |
Tensile strain | Break | ISO527-2 | 3.5 % |
Flexural modulus | | ISO178 | 3750 MPa |
Bending stress | | ISO178 | 135 MPa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | DIN53482 | 1E+15 ohms |
Volume resistivity | | DIN53482 | 1E+15 ohms·cm |
CTI | | IEC60112 | 600 V |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ISO75-2/B | 190 °C |
| | ISO75-2/A | 180 °C |
| | ISO3146 | 220 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.