Basic PerformanceTest ConditionTest MethodTest ResultTest Unit
Melt Volume Flow Rate (MVR)220℃,10kgISO 11337.00CM
densityISO 11831.05
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Shore hardnessISO 2039-1100.0Mpa
Impact strength of cantilever beam gap23℃ISO 180/1A23.0KJ/m
Impact strength of cantilever beam gap-30℃ISO 180/1A10.00KJ/m
Tensile stress23℃,YieldISO 527-146.0Mpa
Tensile modulus23℃ISO 527-12400Mpa
Charpy Notched Impact Strength23℃ISO 179/1eA20.0KJ/m
Charpy Notched Impact Strength-30℃ISO 179/1eA10.00KJ/m
bending strength23℃ISO 17873.0Mpa
Bending modulus23℃ISO 1782350Mpa
Fracture strain23℃ISO 527-115%
Tensile strain23℃,YieldISO 527-13.1%
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature1.80MPa,UnannealedISO 75A-198.0°C
Vicat softening temperature50℃/h 50NISO 306107°C
Linear coefficient of thermal expansion23℃-50℃ISO 11359-10.000090cm/cm℃
Hot deformation temperature0.45MPa,UnannealedISO 75B-1103°C
Combustibility1.60mmUL 94HB
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Shrinkage rateFlow,3.00mmISO 294-40.50-0.80%
Shrinkage rateAcross Flow,3.00mmISO 294-40.50-0.80%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Dielectric strength23℃,1.00mmIEC 60243-138KV/mm
Dielectric loss23℃,1E+6HzIEC 602500.00870
Dielectric loss23℃,100HzIEC 602500.00630
Relative permittivity23℃,1E+6HzIEC 602502.90
Relative permittivity23℃,100HzIEC 602503.00
Volume resistivityIEC 600931E+16ohm.cm
Surface resistivityIEC 600931E+16ohms
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.