PPA HTNFR52G45BL BK337 DUPONT USA
33
Form:Granules | Grade:Flame retardant enhanced grade
Properties:
Dimensional stabilityLow water absorptionHeat aginghigh strengthHigh rigidity
Typical Applications:
household electrical appliancesAutomotive interior partselectrical equipment
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | household electrical appliances | Automotive interior parts | electrical equipment |
| Properties: | Dimensional stability | Low water absorption | Heat aging | high strength | High rigidity |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 45 | kJ/m² |
| 23°C | ISO 179/1eU | 48 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL 94 | V-0 | ||
| Burning wire flammability index | 0.40 mm | IEC 60695-2-12 | 960 | °C |
| 0.75 mm | IEC 60695-2-12 | 960 | °C | |
| 1.5 mm | IEC 60695-2-12 | 960 | °C | |
| 3.0 mm | IEC 60695-2-12 | 960 | °C | |
| Hot filament ignition temperature | 0.40 mm | IEC 60695-2-13 | 700 | °C |
| 0.75 mm | IEC 60695-2-13 | 750 | °C | |
| 1.5 mm | IEC 60695-2-13 | 750 | °C | |
| 3.0 mm | IEC 60695-2-13 | 800 | °C | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2 | 15500 | Mpa | |
| tensile strength | Break | ISO 527-2 | 167 | Mpa |
| Tensile strain | Break | ISO 527-2 | 1.7 | % |
| Bending modulus | ISO 178 | 15100 | Mpa | |
| bending strength | ISO 178 | 249 | Mpa | |
| injection | Test Condition | Test Method | Test Result | Test Unit |
| drying temperature | 100 | °C | ||
| Drying time - hot air dryer | 6.0 to 8.0 | hr | ||
| Suggested maximum moisture content | 0.10 | % | ||
| Processing (melt) temperature | 320 to 325 | °C | ||
| Mold temperature | 90 to 130 | °C | ||
| Drying Recommended | yes | |||
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8 MPa, Unannealed | ISO 75-2/A | 284 | °C |
| Melting temperature | ISO 11357-3 | 310 | °C | |
| Linear coefficient of thermal expansion | Flow | ISO 11359-2 | 1.5E-5 | cm/cm/°C |
| Flow : -40 to 23°C | ISO 11359-2 | 1.3E-5 | cm/cm/°C | |
| Flow : 55 to 160°C | ISO 11359-2 | 1.4E-5 | cm/cm/°C | |
| Across Flow | ISO 11359-2 | 5.0E-5 | cm/cm/°C | |
| Across Flow : -40 to 23°C | ISO 11359-2 | 4.3E-5 | cm/cm/°C | |
| Across Flow : 55 to 160°C | ISO 11359-2 | 8.0E-5 | cm/cm/°C | |
| RTI Elec | 0.40 mm | UL 746 | 140 | °C |
| 0.75 mm | UL 746 | 140 | °C | |
| 1.5 mm | UL 746 | 140 | °C | |
| 3.0 mm | UL 746 | 140 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | 横向Flow | ISO 294-4 | 0.60 | % |
| Flow | ISO 294-4 | 0.20 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | IEC 62631-3-1 | > 1.0E+13 | ohms·m | |
| Dielectric strength | IEC 60243-1 | 40 | KV/mm | |
| Relative permittivity | 1 MHz | IEC 62631-2-1 | 4.40 | |
| 100 Hz | IEC 62631-2-1 | 4.70 | ||
| Dissipation factor | 100 Hz | IEC 62631-2-1 | 6.0E-3 | |
| 1 MHz | IEC 62631-2-1 | 0.012 | ||
| Compared to the anti leakage trace index | IEC 60112 | PLC 0 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.