FEP Dyneon™  6307R2RZ

682

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
melt mass-flow rateASTM D12387.5 g/10 min
flammabilityTest ConditionTest MethodTest Result
Limiting Oxygen IndexASTM D2863> 95 %
Electrical performanceTest ConditionTest MethodTest Result
dielectric constantASTM D150< 2.15
dielectric constantASTM D150< 2.15
Dissipation FactorASTM D150< 3.0E-4
Dissipation FactorASTM D150< 9.0E-4
Thermal performanceTest ConditionTest MethodTest Result
melting temperatureASTM D-1523260 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.